Open Nav

FIG 9095AA

Overfill Prevention Valve - AA Series (3”)

The 9095AA valve is installed at the fill port of a storage tank. Designed for use in pressurized fill systems and requires a tight fill connection. The valve installs in a standard 6” NPT male riser connection and can be set to the desired 90% or 95% shut off level by using standard length pipe nipples.

When installed to the manufacturer’s specifications, the overfill prevention valve can help eliminate hazardous spills. A mechanical test mechanism is available and sold separately. The test mechanism allows a technician to pull the test line at any time during the filling process to actuate the float and stop the fill. This allows a technician to verify the valve is working properly.

For use on clean liquids only.

Product Features

Standard Features

Top fill, remote fill and dry disconnect connections available

Attach 3” Morrison 419 drop tube with the included drop tube adaptor

Adjustable float (1 1/2”)—for setting the precise shut off height

Integrated bleed hole prevents siphoning through the valve

Immediate and cushioned shutoff eliminates line shock

Full flow up to within seconds of valve closure

Integral anti-siphon function

Once closed, the integrated bleed hole featured allows less than 2% of the maximum flow to relieve fill line pressure allowing the fill nozzle to be removed without spilling product

Valve operates on simple mechanics with minimal moving parts. Shutoff is activated by basic hydraulic principles with not springs, levers of complicated sequence leading to valve closure

Typical flow rate is 550 GPM at 10 PSI pressure drop

5 PSI minimum flow requirements. The valve will not work in gravity filling applications


Construction Details

  • Quick disconnect adaptor: Passivated aluminum
  • Remote adaptor: E-coated ductile iron
  • Shaft, linkage, and hardware: Stainless steel
  • Lower pipe nipple: E-coated steel
  • Drop tube adaptor: Passivated aluminum


Code Compliance

ULC-S661-10 listed; NFPA 30, 30A; UFC; IFC; PEI/ RP200; PEI/RP 600; and Florida DEP EQ-851. California EVR models available.

Product Ordering Instructions

Figure

Suffix

Size

Description

Weight (lbs)

9095AA

0300 AV

3”

AST OPV; Aluminum body, w/ 3” male quick disconnect x 6” female threads

21

9095AA

3300AVEVR

3”

AST OPV; Aluminum body, w/ 3” female threaded x 6” female threaded connections; CARB EVR approved

30

9095AF

3301AAPW

3”

Adaptor 3” male thread to 3” raised face flange; for use with 9095AA3300AVEVR

11.1

9095AA

9300AVEVR

3”

AST OPV; Aluminum body, less top connection, CARB EVR approved

14.4

9095B

0300 AV

3”

AST Overfill Prevention Valve (Aluminum Body) w/ 3” Male Quick Disconnect x 6” Female British Threads

29

CLOSE