Open Nav

FIG 244OF

Flanged Emergency Vents

UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire. The vent must be used in conjunction with a “normal vent.” Correct application of this vent requires proper vent size and selection for the tank system in order to meet the specific venting capacity.

WARNINGS: The 244 emergency vent is for emergency pressure relief only and must be used in conjunction with a normal vent or pressure vacuum vent such as a Morrison Fig. 354, 548,748, 749 or 922. The 244 emergency vent must be properly sized and selected for each specific tank application in order to meet the proper venting capacity requirements. See the Morrison Vent Guide for further instructions.

WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILL OPERATE PROPERLY. Morrison tank vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state, and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing temperatures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airflow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank.

Product Video

Product Features

Code Compliance

When properly sized for the tank, this vent will conform to the requirements of the International Fire Code; National Fire Code of Canada; National Fire Protection Agency—NFPA 20, 30, 30A, 31, 37, 110; Petroleum Equipment Institute—PEI RP200, PEI RP800; Underwriters Laboratories Inc.—UL-142, UL-2085, UL-2244; Underwriters Laboratories of Canada—CAN/ULC S601, CAN/ULC S602, CAN/ULC S652


Approvals

California Air Resource Board (CARB) Phase 1 Enhanced Vapor Recovery (EVR) AST Certified Products (VR-402-B); Underwriters Laboratories Inc. UL-2583

*10” 2.5oz vent is UL Listed, but NOT listed to UL 2583

Product Ordering Instructions

Fig Suffix Size Description Weight
244OF 0600 AV* 4” 8oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 11
244OF 0600 AVE 4” 8oz/sq.in. Emergency Vent - Flanged - w/FKM B O-Ring - UL & ULC Listed 11
244OFS 0600 AV 4” 8oz/sq.in. Emergency Vent - Flanged - w/O-Ring, W/Screen - UL & ULC Listed 11
244OF 0170 AV* 4” 16oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 23
244OF 0170AVEVR 4” 16oz/sq.in. Emergency Vent - Flanged - w/FKM B O-Ring - UL & ULC Listed 20
244OFS 0170 AV 4” 16oz/sq.in. Emergency Vent - Flanged - w/O-Ring, W/Screen - UL & ULC Listed 20
244OF 0050 AV* 6” 8oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 21
244OF 0050AVEVR 6” 8oz/sq.in. Emergency Vent - Flanged - w/FKM B O-Ring - UL & ULC Listed 21
244OFS 0050 AV 6” 8oz/sq.in. Emergency Vent - Flanged - w/O-Ring, W/Screen - UL & ULC Listed 21
244OF 0075 AV* 6” 16oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 38
244OF 0075AVEVR 6” 16oz/sq.in. Emergency Vent - Flanged - w/FKM B O-Ring - UL & ULC Listed 38
244OFS 0075 AV 6” 16oz/sq.in. Emergency Vent - Flanged - w/O-Ring, W/Screen - UL & ULC Listed 38
244OF 0100 AV* 8” 8oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 43
244OF 0100AVEVR 8” 8oz/sq.in. Emergency Vent - Flanged - w/FKM B O-Ring - UL & ULC Listed 43
244OF 0200 AV* 8” 16oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 67
244OF 0200AVEVR 8” 16oz/sq.in. Emergency Vent - Flanged - w/FKM B O-Ring, UL & ULC Listed 67
244OF 0300 AV* 10” 2.5oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 25
244OF 0400 AV* 10” 8oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 57
244OF 0400AVEVR 10” 8oz/sq.in. Emergency Vent - Flanged - w/FKM B O-Ring - UL & ULC Listed 57
244OF 0500 AV* 10” 16oz/sq.in. Emergency Vent - Flanged - w/O-Ring - UL & ULC Listed 103
244OF 0500AVEVR 10” 16oz/sq.in. Emergency Vent - Flanged - w/FKM B O-Ring - UL & ULC Listed 103
* Indicates model is available in a kit.
Flanged kits
244OF 04080 AK 4” 8oz/sq.in. Includes 244OF-0600 AV vent, flange adaptor, gasket, and nuts/bolts
244OF 04160 AK 4” 16oz/sq.in. Includes 244OF-0170AVEVR vent, flange adaptor, gasket, and nuts/bolts
244OF 06080 AK 6” 8oz/sq.in. Includes 244OF-0050AVEVR vent, flange adaptor, gasket, and nuts/bolts
244OF 06160 AK 6” 16oz/sq.in. Includes 244OF-0075AVEVR vent, flange adaptor, gasket, and nuts/bolts
244OF 08080 AK 8” 8oz/sq.in. Includes 244OF-0100AVEVR vent, flange adaptor, gasket, and nuts/bolts
244OF 08160 AK 8” 16oz/sq.in. Includes 244OF-0200AVEVR vent, flange adaptor, gasket, and nuts/bolts
244OF 10025 AK 10” 2.5oz/sq.in. Includes 244OF-0300 AV vent, flange adaptor, gasket, and nuts/bolts
244OF 10080 AK 10” 8oz/sq.in. Includes 244OF-0400AVEVR vent, flange adaptor, gasket, and nuts/bolts
244OF 10160 AK 10” 16oz/sq.in. Includes 244OF-0500AVEVR vent, flange adaptor, gasket, and nuts/bolts
CLOSE