FIG 710, 710MO

Solenoid Valve - Normally Closed

Normally closed solenoid valves are used to help prevent the accidental siphoning of product from a tank in the event of a fracture in the pipe or other cause for leak downstream and below the liquid level. Generally installed on the dispensing side of a fuel system pipeline. The valve opens upon the receipt of an electronic signal such as when a dispenser or pump is switched to the on position.

NOTE: Product can only be pumped in one direction, the direction of the flow arrow. Not designed for use as an overfill prevention or process control valve.

Product Features

Standard Features

Normally closed, hung piston design

Install in a horizontal pipeline in the upright vertical position

Minimum operating temperature is -40°F

Zero pressure differential

Integral thermal relief allows the valve to relieve expansion pressure in the opposite direction of flow

Continuous duty Class H standard coil operates at 120 volts

Enclosure is watertight and rated for hazardous locations—NEMA 3, 4X, 7 and 9; groups C and D

Several optional coil voltages available

710MO has manual override feature. Available in sizes ranging from ¾″ to 2″ for operation during a power outage

Recommended for use with liquids having a maximum viscosity of 60 centistokes

A strainer with a 100 mesh screen is recommended at the valve inlet


Construction Details

  • Body: Cast bronze
  • Seals: FKM, PTFE
  • Piston: Brass (3/4”-2” models) or aluminum (3” models)
  • Solenoid housed in an integral, watertight, explosion-proof shell


Certifications & Listings

CSA listed (File No. 108921, Model Z1314); Class I, Groups C and D; Class II, Groups E, F and G; Class III; T3C; cULus listed

Product Ordering Instructions

Figure Suffix Size Description Weight (lbs)
710 0075 1V .75” Solenoid Valve (FKM) w/120/60 Volt AC Coil 11
710 0100 1V 1” Solenoid Valve (FKM) w/120/60 Volt AC Coil 13
710 0150 1V 1.5” Solenoid Valve (FKM) w/120/60 Volt AC Coil 16
710 0200 1V 2” Solenoid Valve (FKM) w/120/60 Volt AC Coil 21
710 0300 1V 3” Solenoid Valve (FKM) w/120/60 Volt AC Coil 44
710MO 0075 1V .75” Solenoid Valve (FKM) w/120/60 Volt AC Coil w/ Manual Override 12
710MO 0100 1V 1” Solenoid Valve (FKM) w/120/60 Volt AC Coil w/ Manual Override 14
710MO 0150 1V 1.5” Solenoid Valve (FKM) w/120/60 Volt AC Coil w/ Manual Override 17
710MO 0200 1V 2” Solenoid Valve (FKM) w/120/60 Volt AC Coil w/ Manual Override 22



*Contact Customer Service for other options and voltages.