Open Nav

FIG 9095SS

Overfill Prevention Valve - SS Series

The 9095SS valve is installed at the fill port of a storage tank. Designed for use in pressurized fill systems and requires a tight fill connection. The valve installs on a 2” NPT male riser connection on low profile tanks requiring a high level shut-off. The valve terminates the fill when the product reaches the preset level. Compatible for use with diesel exhaust fluid (DEF).

 

Maximum Pressure- 100 PSI

Maximum Viscosity- 150 Centistokes

For use on clean liquids only.

Product Features

Standard Features

Designed for fill applications that do not require a drop tube

Can be field adjusted to the desired 90% or 95% shut off level by adjusting the shut-off tube

The valve design allows for full product flow until it reached the shut-off level

Typical flow rate is 110 GPM at 10 PSI pressure drop

5 PSI is the minimum flow requirement for the valve to operate. The valve will not work in gravity filling applications

Can be retrofitted to existing tanks

Integral pressure relief

The vertical style float allows for installation in openings in close proximity to the tank wall

Immediate and cushioned shutoff…full flow up to within 1-2 seconds of closing and no abrupt kickback or line shock when valve closes

Dry disconnect…after shut off product is allowed to automatically drain from the highest point so fill nozzle can be removed without spilling

Simple mechanics…minimum moving parts. Shutoff is activated by basic hydraulic principle with no springs, levers or complicated sequence leading to closure

 


 

Construction Details

  • Adaptor: Stainless steel Part A or stainless steel Part F
  • Body: Stainless steel
  • Float: Polypropylene
  • Plunger and dashpot: Stainless steel
  • Upper tube and float guard: Stainless steel
  • Shut off mechanism: Stainless steel

 


 

Code Compliance

Florida DEP EQ-858, NFPA 30, 30A, UFC, IFC, PEI/RP 200, and PEI/RP 600

Product Ordering Instructions

FigSuffixSizeDescriptionWeight
9095SS0200 AV2”SS Overfill Prevention Valve 2I to 16I With Part F Male Adaptor8.2
9095SS0400 AV2”SS Overfill Prevention Valve 2I to 28I With Part F Male Adaptor8.2
9095SS0600 AV2”SS Overfill Prevention Valve 2I to 76I With Part F Male Adaptor8.2
9095SS2200 AV2”SS Overfill Prevention Valve 2I to 16I With Part A Female Adaptor8.2
9095SS2400 AV2”SS Overfill Prevention Valve 2I to 28I With Part A Female Adaptor8.2
9095SS2600 AV2”SS Overfill Prevention Valve 2I to 76I With Part A Female Adaptor8.2
9095SS9200 AV2”SS Overfill Prevention Valve 2I to 16I Without Adaptor7.5
9095SS9400 AV2”SS Overfill Prevention Valve 2I to 28I Without Adaptor7.5
9095SS9600 AV2”SS Overfill Prevention Valve 2I to 76I Without Adaptor7.5
9095SS9800 AV2”SS Overfill Prevention Valve 2I to 96I Without Adaptor7.0